CSMS-A15
Uc:
AC385V/420V/440V
Iimp (10/350 μs):
15kA
In (8/20 μs):
50kA
Imax(8/20 μs):
100kA
Mode of Protection:
L-N/N-PE;L-N,N-PEReference Standards:
IEC 61643-11OEM/ODM Acceptable
Additional Function:
Thermal Tripping Protection, Status Indicator, and Remote SignalingTechnical Parameters
| SPD Model | CSMS-A15 | |||||
| Protected mode | L/N-PE | L-N,N-PE | L/N-PE | L-N,N-PE | L/N-PE | L-N,N-PE |
| Maximum continuous operating voltage Uc (V) | AC385V | L-N:AC385V; | AC420V | L-N:AC420V; | AC440V | L-N:AC440V; |
| N-PE:AC260V | N-PE:AC260V | N-PE:AC260V | ||||
| Impulse discharge current Iimp (10/350 μs) | 15kA | 15kA | 15kA | |||
| Nominal discharge current In(8/20µs) | 50kA | 50kA | 50kA | |||
| Maximum discharge current Imax(8/20µs) | 100kA | 100kA | 100kA | |||
| Voltage protection level Up | ≤2.0kV | L-N:≤2.0kV; | ≤2.1kV | L-N:≤2.1kV; | ≤2.1kV | L-N:≤2.1kV; |
| N-PE:≤1.5kV | N-PE:≤1.5kV | N-PE:≤1.5kV | ||||
| Response time | ≤25ns | L-N:≤25ns; | ≤25ns | L-N:≤25ns; | ≤25ns | L-N:≤25ns; |
| N-PE:≤100ns | N-PE:≤100ns | N-PE:≤100ns | ||||
| Leakage current | 0μA | L-N:0μA | 0μA | L-N:0μA | 0μA | L-N:0μA |
| N-PE:0μA | N-PE:0μA | N-PE:0μA | ||||
| Follow current interrupting rating Ifi | - | 100Arms | - | 100Arms | - | 100Arms |
| Sectional area of Wire | 6-35mm² | |||||
| Maximum backup fuse | 125A gl/gG | |||||
| Connection type | Terminal wiring (torque: 2.5Nm) | |||||
| Remote signal contact point | Optional(Alarm contact strength AC:250V/0.5A,125V/2A; DC:30V/2A)(torque:0.25Nm)(Sectional area of Wire:0.5-1.5mm²) | |||||
| 485 Communication | Optional | |||||
| Dimensions | 36mm/P | 36mm/P | 36mm/P | |||
| Number of Poles | 1P、2P、3P、4P | 1P+N、3P+N | 1P、2P、3P、4P | 1P+N、3P+N | 1P、2P、3P、4P | 1P+N、3P+N |
| Case material | Flame retardant plastic | |||||
| Mounting | DIN rail 35 mm | |||||
| Reference Standards | IEC61643-11;GB/T18802.11 | |||||
| Ambient air temperature for operation | -40℃~+80℃ | |||||
| Ambient air temperature for storage | ||||||
| Relative humidity | 5~95%(No condensation) | |||||
| Degree of protection of enclosure (IP code) | IP20 | |||||
| Operating altitude | ≤3000m | |||||
| Atmosphere pressure | 70kPa~106kPa | |||||
| Warranty period | 3 years | |||||
SPD Schematic
|
3P+N SPD Schematic |
4P SPD Schematic |
Wiring Diagram
|
3P+N SPD Wiring Diagram |
4P SPD Wiring Diagram |
Dimensions (mm)
|
CSMS-A15 Dimension figure |
RELATED PRODUCTS
AC Power SPD->Type 1 / Class l
Uc:
AC385V/420V/440V
Iimp (10/350 μs):
25kA
In (8/20 μs):
60kA
Imax(8/20 μs):
100kA
Mode of Protection:
L/N-PE; L-N, N-PEReference Standards:
IEC 61643-11OEM/ODM Acceptable
Additional Function:
Thermal Tripping Protection, Status Indicator, and Remote SignalingAC Power SPD->Type 2 / Class ll
Uc:
AC385V/420V/440V
In (8/20 μs):
60kA
Imax(8/20 μs):
100kA
Mode of Protection:
L/N-PE; L-N, N-PEReference Standards:
IEC 61643-11OEM/ODM Acceptable
Additional Function:
Thermal Tripping Protection, Status Indicator, and Remote SignalingShandong Cresin Electric Co., Ltd. Privacy Policy
Contact Us
Address: No. 978 Tianchen Road, High-tech Zone, Jinan, Shandong,China
CAN’T FIND THE PRODUCT?
The product range includes production technologies for smart capacitors, digital display meters, surge protectors, dedicated backup protection devices for surge protectors, self-resetting over/under-voltage protectors, control and protection switches, and automatic transfer switches for dual power supplies.
Search HistoryClear All Records
- 全部
- 产品管理
- 新闻资讯
- 介绍内容
- 企业网点
- 常见问题
- 企业视频