Power Distribution Surge Protection

Power distribution systems are the core electrical infrastructure in buildings, factories, commercial facilities and industrial sites. Surges may enter through incoming power lines, switching operations, inductive loads or nearby lightning activity. Without proper protection, electrical equipment may suffer insulation breakdown, control failure or unexpected shutdown. A layered surge protection design is recommended for low-voltage distribution systems, including main distribution protection, sub-distribution protection and terminal equipment protection.

Low-voltage main switchgear incoming feeder

Tiered protection for the main cabinet, suitable for 220/380V TN-S systems.

CSMS-A25

AC Power SPD->Type 1 / Class l

Uc:

AC385V/420V/440V

Iimp (10/350 μs):

25kA

In (8/20 μs):

60kA

Imax(8/20 μs):

100kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Distribution cabinet / Feeder cabinet

Secondary protection to limit residual voltage downstream of the main cabinet.

CSMS-B100

AC Power SPD->Type 2 / Class ll

Uc:

AC385V/420V/440V

In (8/20 μs):

60kA

Imax(8/20 μs):

100kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Terminal distribution box / Equipment cabinet

Fine-level protection at the load end to safeguard pumps, fans, and control power supplies.

CSMS-B40

AC Power SPD->Type 2 / Class ll

Uc:

AC385V/420V/440V

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Water pump / Building control signal cables

Protection for 24V control, telemetry, and remote control signals.

CSMS-TEL

Signal & Data SPD

Uc(V) :

15V/30V/60V

Un(V) :

12V/24V/48V

In (8/20 μs):

5kA

Imax(8/20 μs):

10kA

Reference Standards:

IEC 61643-21

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

FAQ

Can CRESIN provide SPD for industrial distribution panels?

Yes. CRESIN can provide AC SPD products for main distribution panels, sub-panels, control cabinets, industrial machinery, and building electrical systems.

Is grounding necessary for distribution SPD?

Yes. A reliable grounding system is necessary for SPD to safely discharge surge energy and provide effective protection.

How do I choose SPD for a distribution cabinet?

You need to confirm the system voltage, grounding system, number of phases, installation position, required discharge current, and protection level.

What is coordinated surge protection?

Coordinated surge protection means using different SPD levels at different installation points, such as Type 1 at the main incoming side, Type 2 at sub-distribution boards, and then step-by-step coordination enables the gradual release of electrical energy.

Where should SPD be installed in a distribution system?

SPD is commonly installed at the main distribution board, sub-distribution board, control cabinet, machinery panel, and near sensitive electrical equipment.

Why do power distribution systems need surge protection?

Power distribution systems can be affected by lightning surges, switching operations, grid disturbances, and transient overvoltage. SPD helps protect downstream electrical equipment and reduce failure risk.


Shandong Cresin Electric Co., Ltd.    SEO   CEGLOBAL     Privacy Policy

Follow Us

Contact Us

Address: No. 978 Tianchen Road, High-tech Zone, Jinan, Shandong,China

CAN’T FIND THE PRODUCT?

The product range includes production technologies for smart capacitors, digital display meters, surge protectors, dedicated backup protection devices for surge protectors, self-resetting over/under-voltage protectors, control and protection switches, and automatic transfer switches for dual power supplies.

Search HistoryClear All Records
Up to 8 search history entries will be displayed.~
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频

LEAVE US A MESSAGE