Industrial Automation Surge Protection

Industrial automation systems use PLCs, sensors, actuators, control panels, communication modules and power supplies. These devices are sensitive to transient overvoltage caused by lightning, switching operations, motor starting, relay operation and inductive load interference. Surge protection should be considered for power supply circuits, signal circuits, communication lines and control cabinets.

Main power distribution cabinet incoming line terminal

Photovoltaic DC-side Type 2 (T2) SPD; select DC 600/1000/1200/1500 V based on system voltage.

CSMS-A25

AC Power SPD->Type 1 / Class l

Uc:

AC385V/420V/440V

Iimp (10/350 μs):

25kA

In (8/20 μs):

60kA

Imax(8/20 μs):

100kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

PLC/control cabinet power supply input

Suppresses DC surges between the PV modules and the inverter.

CSMS-B40

DC Power SPD

Un(V):

DC12/24/48/120/220/380/750/1000

Uc(V):

DC15/30/60/175/275/505/1060/1200

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations

CSMS-B40

AC Power SPD->Type 2 / Class ll

Uc:

AC385V/420V/440V

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

VFD/MCC cabinet incoming line

AC secondary protection; protects low-voltage equipment on the grid-connection side.

CSMS-B60

AC Power SPD->Type 2 / Class ll

Uc:

AC385V/420V/440V

In (8/20 μs):

30kA

Imax(8/20 μs):

60kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Field sensor/actuator signal cables

AC primary protection; located at the boundary between LPZ 0B and LPZ 1.

CSMS-B40

DC Power SPD

Un(V):

DC12/24/48/120/220/380/750/1000

Uc(V):

DC15/30/60/175/275/505/1060/1200

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE; L-N, N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Industrial switch/remote I/O network port

Provides protection for Ethernet and 24V/analog signal lines, respectively.

CSMS-RJ45

Signal & Data SPD

Uc(V) :

8V

Un(V) :

5V

In (8/20 μs):

10kA

Imax(8/20 μs):

20kA

Reference Standards:

IEC 61643-21

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

FAQ

What information is needed for automation SPD selection?

You need to provide power voltage, signal type, communication protocol, cable length, installation environment, grounding condition, and protected equipment type.

Where should SPD be installed in industrial control systems?

SPD should be installed at power input points, cabinet cable entry points, communication interfaces, sensor line entrances, and near sensitive control equipment.

What type of SPD is used for RS485 communication?

RS485 systems require signal SPD designed for low-voltage communication lines. The SPD should match the working voltage, number of wires, transmission speed, and communication structure.

Can surge protection protect PLC systems?

Yes. Properly selected SPD can help protect PLC power supplies, communication modules, I/O modules, and connected field devices from surge damage.

What parts of an automation system need SPD?

SPD may be needed for AC power supply lines, DC power circuits, PLC input/output lines, RS485 communication lines, sensor lines, Ethernet networks, and control cabinets.

Why do industrial automation systems need surge protection?

Industrial automation systems include PLCs, sensors, control cabinets, communication networks, and power supplies. These components are sensitive to transient overvoltage caused by switching operations, lightning-induced surges, and electrical interference.


Shandong Cresin Electric Co., Ltd.    SEO   CEGLOBAL     Privacy Policy

Follow Us

Contact Us

Address: No. 978 Tianchen Road, High-tech Zone, Jinan, Shandong,China

CAN’T FIND THE PRODUCT?

The product range includes production technologies for smart capacitors, digital display meters, surge protectors, dedicated backup protection devices for surge protectors, self-resetting over/under-voltage protectors, control and protection switches, and automatic transfer switches for dual power supplies.

Search HistoryClear All Records
Up to 8 search history entries will be displayed.~
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频

LEAVE US A MESSAGE