Wind Power System Surge Protection

Wind turbines are installed in exposed environments such as mountains, coastlines, grasslands and offshore areas. Because of their height and location, wind turbines are naturally more exposed to lightning activity. Lightning surges may enter through power lines, control cables, communication systems and grounding paths. A reliable wind power surge protection system should protect the turbine nacelle, tower base electrical cabinet, converter system, transformer area, monitoring system and communication network.

Tower base control cabinet / Auxiliary power supply

Protects 220/380V control and auxiliary power supplies.

CSMS-B40

Wind Power SPD->Type 2 / Class ll

Uc(V):

AC760V/1500V

Un(V):

AC690V/1140V

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

SCADA / Sensor communication cables

Protects network, status, analog, and remote control signal lines.

CSMS-TEL

Signal & Data SPD

Uc(V) :

15V/30V/60V

Un(V) :

12V/24V/48V

In (8/20 μs):

5kA

Imax(8/20 μs):

10kA

Reference Standards:

IEC 61643-21

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations

CSMS-RJ45

Signal & Data SPD

Uc(V) :

8V

Un(V) :

5V

In (8/20 μs):

10kA

Imax(8/20 μs):

20kA

Reference Standards:

IEC 61643-21

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Pad-mounted transformer low-voltage side / Wind turbine grid-connection side

Provides primary protection on the low-voltage side of the box-type substation, given the exposed environment of the wind farm.

CSMS-A25

Wind Power SPD->Type 1 / Class l

Uc(V):

AC760V/1500V

Un(V):

AC690V/1140V

In (8/20 μs):

25kA

Imax(8/20 μs):

50kA

Mode of Protection:

L/N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

Wind measurement / Monitoring mast equipment enclosure

Protects outdoor monitoring, meteorological, and communication lines.

CSMS-RJ45

Signal & Data SPD

Uc(V) :

8V

Un(V) :

5V

In (8/20 μs):

10kA

Imax(8/20 μs):

20kA

Reference Standards:

IEC 61643-21

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations

CSMS-B40

Wind Power SPD->Type 2 / Class ll

Uc(V):

AC760V/1500V

Un(V):

AC690V/1140V

In (8/20 μs):

20kA

Imax(8/20 μs):

40kA

Mode of Protection:

L/N-PE

Reference Standards:

IEC 61643-11

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations

CSMS-SV2L

CCTV & Security SPD

Uc(V) :

DC40V/AC320V

Un(V) :

DC24V/AC220V

In (8/20 μs):

10kA

Imax(8/20 μs):

20kA

Reference Standards:

IEC61643

OEM/ODM Acceptable

Additional Function:

Thermal Tripping Protection, Status Indicator, and Remote Signaling
View Details & Configurations
< 1 >

FAQ

What information is needed for wind power SPD selection?

You need to provide turbine system voltage, cabinet layout, signal type, grounding system, installation position, and project protection requirements.

Can CRESIN provide SPD for wind farm communication systems?

Yes. CRESIN can provide surge protection for RS485, Ethernet, telecom, monitoring, and control signal lines used in wind power systems.

Do wind turbines require both power SPD and signal SPD?

Yes. Wind turbines usually require power SPD for electrical distribution and signal SPD for communication, sensor, and control lines.

What equipment in wind power systems is sensitive to surges?

Sensitive equipment includes sensors, communication modules, inverter, control cabinets, monitoring systems, pitch control systems, and grid-connected electrical equipment.

Where should SPD be installed in a wind turbine system?

SPD can be installed in the nacelle control cabinet, tower base cabinet, converter cabinet, generator system, communication lines, sensor lines, and power distribution system.


Shandong Cresin Electric Co., Ltd.    SEO   CEGLOBAL     Privacy Policy

Follow Us

Contact Us

Address: No. 978 Tianchen Road, High-tech Zone, Jinan, Shandong,China

CAN’T FIND THE PRODUCT?

The product range includes production technologies for smart capacitors, digital display meters, surge protectors, dedicated backup protection devices for surge protectors, self-resetting over/under-voltage protectors, control and protection switches, and automatic transfer switches for dual power supplies.

Search HistoryClear All Records
Up to 8 search history entries will be displayed.~
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频

LEAVE US A MESSAGE